Sign In | Join Free | My frbiz.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Used Ultrasound Transducer >

GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7

Brand Name : GE

Model Number : 3Sc-RS

MOQ : 1

Payment Terms : T/T, Western Union,PayPal

Delivery Time : 3-5 working days

Product name : GE Ultransound PHiliphased Array probe

Type : 3Sc-RS

Application : Ultrasound Machine

Warranty : 90days

Color : White

product label : Ultrasound Transducer Probe

Apply For : Ultrasound Machine

Materials : PCB,Plastic,etc

Competitive Edge : Original

Product State : In Good Condition

Rated Voltage Forge : 110V—240v

Footprint : 18 x 24 mm

Features Introduction : Useful,Durable,Reliable

Minimum purchase commitment : 1 unit

Frequency Max : 9 MHz

Frequency Min : 3 MHz

Field of View : 120°

Depth of Field : 30 cm

Contact Now

GE Ultransound 3Sc-RS PHiliphhilipased Array probe for Vivid S60 Vivid T8 Vivid S5 Vivid iq Vivid i LOGIQ P9 LOGIQ e LOGIQ e R7

Brief Introduction

GE 3Sc-RS Wide Band PHiliphhilipased Array Probe is Applications: Abdomen, Obstetrics, Gynecology, Basic Cardiac, fetal heart, Vascular, Urology, Pediatric/Neonatal, transcranial, coronary, stress, LVO contrast, LVO stress, vascular, ED (FAST, Pleural, Orbits).

Helps improve near field imaging, decreases vessel fill-in, increases contrast and detail resolution and helps provide optimized imaging.

Excellent contrast resolution is identified scanning the heart

Adult Echo Color Doppler - The 3Sc PHiliphhilipased array cardiac probe combines acoustic amplifier technology and an advanced heat dissipation regime to provide ultra-wide bandwith and highend image quality.

Specifications

Main Applications Description Mode Footprint Biopsy Guide Scanner Frequency Range Field of View Depth of Field
Cardiac, Pediatric, Abdominal, Fetal, Adult CePHiliphhilipalic PHiliphhilipased Array 2D-Mode
M-Mode
Color Flow
CW Doppler
PW Doppler
18 x 24 mm Multi-angle disposable, with a reusable bracket 1.3 - 4.0 MHz 120° 30 cm

The 3Sc-RS probe is compatible with:

  • Vivid S60
  • Vivid T8
  • Vivid S5
  • Vivid iq
  • Vivid i
  • LOGIQ P9
  • LOGIQ e
  • LOGIQ e R7

Connect the probe

Probes can be connected at any time, whether the system is on or off.

  1. Before connecting the probe:

• Inspect the probe and the probe cable for any damage.

• Do a visual check of the probe pins and system sockets. Remove any dust or foam remains from the probe pins.

  1. Hold the probe connector vertically with the cable pointing upward.
  2. Turn the connector locking handle counterclockwise.
  3. Align the connector with the probe port and carefully push into place.
  4. Turn the locking handle clockwise to the full vertical position to lock in place.
  5. Position the probe cable so that it is not resting on the floor.

► Probe Manual Cleaning Instructions

  1. Put on a clean pair of gloves and fill a sink or basin with warm potable water (30 - 40°C) to a level allowing immersion of the probe up to the immersion line shown.
  2. Prepare the cleaning solution in accordance with the disinfectant manufacturer’s instructions.
  3. Immerse the probe in the prepared cleaning solution up to the immersion line and ensure no air bubbles are trapped on the surface. Do not submerge probe beyond the immersion line shown.

Storing probes
It is recommended that all probes be stored in the carrying case provided.

  • First place the probe connector into the carrying case.
  • Carefully wind the cable into the carrying case.
  • Carefully place the probe head into the carrying case. DO NOT use excessive force or impact the probe face.

For any additional questions or concerns regarding GE Ultransound 3Sc-RS PHiliphhilipased Array probe for Vivid S60 Vivid T8 Vivid S5 Vivid iq Vivid i LOGIQ P9 LOGIQ e LOGIQ e R7, please feel free to contact us.If you want to explore more details please let us know.


Product Tags:

GE Ultransound 3Sc-RS PHiliphased Array Probe

      

Vivid S60 PHiliphased Array Probe

      

Ultrasound Transducer Probe

      
China GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 wholesale

GE Ultransound 3Sc-RS PHiliphased Array Probe For Vivid S60 Vivid T8 Vivid S5 Vivid Iq Vivid I LOGIQ P9 LOGIQ E LOGIQ E R7 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)